Specifications: Inputs; NPN (+ common); 16 points.
I/O connections: M3 Screw terminals.
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
of the control system.
on the communications power supply.
and equipment operating information.
Expansion via Expansion I/O Units.
maintenance is easier.
Name: System Units; I/O Power Feed Unit.
Specifications: Use to add V/G terminals,
for I/O power supply.
Standards: CE, UC, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON DRT2-ID16.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
DRT2-ID16
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Classification: Analog input.
I/O points: 4 inputs (Resolution: 30, 000) OMRON DRT2-ID16.
Performs Calculations on Analog Values within the Slave Itself.
Also Provides High Resolution at 1/30,000 (Full Scale) and,
Support for a Wide Variety of Data Sampling.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities.
Sampling data can be analyzed internally to provide a low-cost scheduler function OMRON DRT2-ID16.
Equipped with functions such as the scaling function, peak/bottom hold;
top/valley hold; comparator function, cumulative counter, and derivative,
calculation function.
Two I/O points can be allocated to any two of the following values: analog,
input, peak/bottom, top, valley, or rate-of-change OMRON Transistor Remote I/O Terminals. Values without an,
allocated I/O point can be read with message communications. Name: Expansion Units e-CON Connector type OMRON Transistor Remote I/O Terminals.
Specifications:Digital inputs and outputs;
4 inputs/ 4 outputs; PNP;
One Expansion Unit can be mounted to one,
CRT1-VAD02@@D or CRT1-VDA02@@D Analog I/O Slave Unit.
Standards: --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON Transistor Remote I/O Terminals.
Branching is easily made with CompoNet.
Wiring material cosst can be reduced DRT2-ID16.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee OMRON DRT2-ID16.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.