LK Automation Limited
Home >> Products >> OMRON >> Temperature controller >> input device >> E52-CA20AF D=16 NETU 2M Temperature Sensor OMRON E52-CA20AF D=16 NETU 2M Protective tubing diameter D(mm): 16 dia 

E52-CA20AF D=16 NETU 2M Temperature Sensor OMRON E52-CA20AF D=16 NETU 2M Protective tubing diameter D(mm): 16 dia 

Brand: OMRON
Name: Temperature Sensor
Model: E52-CA20AF D=1.6 NETU 2M
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1.6 dia.
Protective tubing length L: 20 cm.
Lead wire type: Heat resistive.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal.

Size: 96 × 96 mm.
Control type: Position-proportional control(1 loop).
Control mode: Single-loop position-proportional control(See note.).
Outputs(control/transfer): Relay output(1 open, 1 close) and,
1 current (transfer) output.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 4; Serial communications, RS-485 OMRON E52-CA20AF D=1.6 NETU 2M.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity E52-CA20AF D=1.6 NETU 2M
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller OMRON E52-CA20AF D=1.6 NETU 2M.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming OMRON E52-CA20AF D=1.6 NETU 2M. Control output: Linear current output *1.
Auxiliary output: --.
Communications: RS-485.
Heater burnot: --.
Event inputs: --.
Power supply voltage: 24 VAC/VDC OMRON Temperature Sensor.
The E5DC-800 Mounts to DIN Track and Is Ideal,
for Connections to HMIs and PLCs.
It provides the Same Easy Operation and,
Advanced Performance as the Rest of the,
E5@C-800 Series OMRON Temperature Sensor.
A slim body at 85 × 22.5 mm (D × W) that fits into narrow control,
panels and mounts to DIN Track.
Removable terminal block for easy replacement to simplify maintenance.
High-speed sampling at 50 ms for applications with high-speed,
temperature increases OMRON Temperature Sensor.
Easy connections to a PLC with programless communications.
Models are available with up to 2 auxiliary outputs and 1 event input to,
complete basic functions.
A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel. Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2.
Control outputs 3 and 4: Transistor output: 2 points (sinking).
Auxiliary output: None.
Functions: burnout Heater alarm, 2 *3; Event inputs, 2 .
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi--channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E52-CA20AF D=1.6 NETU 2M.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullate the PID constants with the step,
response method OMRON E52-CA20AF D=1.6 NETU 2M.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.


...More relevant models >>>>