LK Automation Limited
Home >> Products >> OMRON >> Temperature controller >> input device >> E52-CA35AF D=16 NETU 2M OMRON E52-CA35AF D=16 NETU 2M Protective tubing diameter D(mm): 16 dia Temperature Sensor

E52-CA35AF D=16 NETU 2M OMRON E52-CA35AF D=16 NETU 2M Protective tubing diameter D(mm): 16 dia Temperature Sensor

Brand: OMRON
Name: Temperature Sensor
Model: E52-CA35AF D=1.6 NETU 2M
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1.6 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal.

Size: 1/8DIN 48 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Analog (Current, Voltage) Input Type.
Control method: Valve Control.
Number of alarms: 2.
Communica- tions function: None.
Event input: None.
A position proportional control model for the E5EZ-PRR series OMRON E52-CA35AF D=1.6 NETU 2M.
Depth of only 78 mm.
Various temperature inputs (thermocouple, platinum resistance thermometer,
infrared temperature sensor, voltage inputs) and analog inputs (current, voltage),
Makes use of high-visibility LCD, with three lines of 4-digit display,
for simplicity E52-CA35AF D=1.6 NETU 2M
and clarity.
3 lines of display to observe PV/ SV/ MV (valve open percentage),
clearly displaying the state of control (operations) OMRON E52-CA35AF D=1.6 NETU 2M.
Event input enables multi-SP selection and run/ stop function.
Alarm delay function.
Communications function.
Able to choose closed/floating control. In floating control,
position proportional control can be performed without a potentiometer,
Equipped with a manual output function (equipped with an automatic/manual key),
CE marking and UL/CSA certification. Control output: voltage output (SSR driver) OMRON E52-CA35AF D=1.6 NETU 2M.
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit) OMRON Temperature Sensor.
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type OMRON Temperature Sensor.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating OMRON Temperature Sensor.
Easy to connect with PLC through no program communication.
The use of communication adapter cablle (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E52-CA35AF D=1.6 NETU 2M.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete OMRON E52-CA35AF D=1.6 NETU 2M.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).


...More relevant models >>>>