FA-TH16YRAB20SL MITSUBISHI FA-TH16YRAB20SL

Brand: MITSUBISHI
Name: Terminal module
Model: FA-TH16YRAB20SL
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.

Output points: 32 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: output 32 points).
External wiring connection mode: 40 pin connector MITSUBISHI FA-TH16YRAB20SL.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called FA-TH16YRAB20SL
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol MITSUBISHI FA-TH16YRAB20SL. Convert connector to screw relay terminal.
2 wire connection, no need to use common terminal.
Positive common end use. Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Positive common end use. Can be isolated to obtain DC24/48/100V, AC100/200V input signal MITSUBISHI FA-TH16YRAB20SL. Input points: 16 points.
Rated input voltage: DC24V.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on MITSUBISHI Conversion module MITSUBISHI Conversion module MITSUBISHI Conversion module. Output points: 32 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: output 32 points).
External wiring connection mode: 40 pin connector.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called FA-TH16YRAB20SL.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can alsso be carried out through the RS-485 bus communication,
Remote control switch MITSUBISHI FA-TH16YRAB20SL.
Communication protocol is a standard Modbus protocol or custom protocol.