Operation/resetting system: Time-limit operation/self-resetting.
Time-limit contact: DPDT(for power switching).
Time ranges: 0.04 s to 3 h.
Supply voltage: 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 100 to 110 VDC.
Mounting: Surface/DIN-track mounting (with socket).
Miniature Timer Compatible with the MY.
Relay.
UL listed when used with a Push-In Plus Terminal Block Socket.
Conforms to CSA, CE Marking, CCC and LR.
terminals on bottom.
Large transparent time setting knob facilitates time setting.
A flat-blade and Phillips screwdriver can also be used for time setting.
Semi-multi power supply voltage.
Input type: DC voltage input type.
Output type: linear; voltage; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with OMRON H3Y-2-B.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
H3Y-2-B
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNeCategory: external supply 100mA DC10V OMRON H3Y-2-B.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified OMRON H3Y-2-B.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trendControl cycle: Yearly OMRON Solid-state Timer.
Number of outputs: 4 circuits.
Mounting method: Flush mounting.
Supply voltage: 100 to 240 VAC.
Easier, More Convenient Time Switches, with,
New 4-circuit Output and Yearly Models in,
Addition to 2-circuit Weekly Models OMRON Solid-state Timer.
Independent Day Keys provide easier operation.
Temporary holiday setting function makes it easy to turn OFF,
output for holidays and non-operating days.
Settings can be made even with the Time Switch turned OFF OMRON Solid-state Timer.
Test mode enables easy program checking.
Complies with EMC Directives, UL/CSA, and other safety standards.
Includes summer time (DST) adjustment.
Yearly models also offer automatic switching to DST.
Set value can be changed both upward and downward for sspeedier setting H3Y-2-B.
Integrated temperature compensation circuit helps keep,
accurate time over a wide temperature range. (See note 1.)
Includes time counter and total counter functions with alarm,
indicator. (See note 2.)
Bank functioon allows program switching by an external input OMRON H3Y-2-B.
(See note 3.)
New 4-circuit output models with a compact, 72 × 72-mm DIN,
size added to the series.