A1SI61 is designed to control the application of mechanical devices that require high speed response time.
A1SI61 temporarily stop running in order to generate an interrupt signal when the program is running,
And according to the interrupt vector to execute the corresponding interrupt handler.
The interrupt start condition can be selected according to the type of the connected device,
That is, the rising edge of the interrupt signal can be selected as a starting signal, and the falling edge of the interrupt signal can be selected as an interrupt.
The popularization and application of PLC programming has been developed rapidly in our country,
It has been widely used in all kinds of mechanical equipment and production process of electrical control devices,
All walks of life have emerged a large number of application of PLC transformation of the results of the equipment.
Understand the working principle of PLC, have the ability to design, debug and maintain the PLC control system,
Has become the basic requirements of modern industry for electrical technicians and engineering students.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations.
In the case of the computer for the PLC handheld programmer compile user program.
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC.
The characteristics of instruction table programming language is used to represent mnemonic operation function,
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-to-one correspondence between the ladder diagram and the ladder diagram. Its characteristics are basically consistent with the ladder diagram language.
8 channel analog input module.
This is a high density of 8 channel A/D components,
Can receive voltage and current input, with the installation of the inside of the cover plate switch,
The input type and range of each channel can be set up according to the application requirements:
12 bit resolution,
Automatic drift correction function,
0 MITSUBISHI A1SI61. 5msec/1 channel,
-10-0-10V or 0-20mA input
A1SI61 Input type: AC.
Input points: 16 points.
Input voltage: AC100-120V.
Input current: 7mA.
Connection mode: terminal row.
Common common point: 16.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations MITSUBISHI A1SI61.
In the case of the computer for the PLC handheld programmer compile user program.
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC.
The characteristics of instruction table programming language is used to represent mnemonic operation function,
Easy to remember, easy to grasp;
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-to-one correspondence between the ladder diagram and the ladder diagram MITSUBISHI A1SI61 MITSUBISHI High speed interrupt module. Its characteristics are basically consistent with the ladder diagram language MITSUBISHI High speed interrupt module. Output type: transistor source / drain type.
Output points: 8 points.
Load voltage: DC5/12/24/48.
Load current: 2A.
Connection mode: terminal row.
Common public end points: 1.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC MITSUBISHI High speed interrupt module.
Switch volume control is designed to,
According to the current input combinatiion of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order A1SI61.
So, sometimes also known as the order control.
And seqquential control is divided into manual, semi-automatic or automatic MITSUBISHI A1SI61.
And the control principle is decentralized, centralized and hybrid control three.