Type: medium temperature.
Measuring temperature range: 0 ~ +500.
The target size: 3mm diameter (from 30mm).
No need to contact the workpiece, you can measure the temperature.
Achieve no damage, health and efficient temperature management.
A small spot diameter 3mm and 8mm diameter two types.
Reproduction of positive and negative 0.5 degrees Celsius, response speed of 0.4 seconds,
(95%) with high precision and high speed measurement.
High temperature (0 ~ +1000 degrees C) models.
New measurement distance up to 500mm, 1000mm long distance type.
Moving average function and output range.
The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function OMRON ES1-LP3
ES1-LP3
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type OMRON ES1-LP3.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling OMRON ES1-LP3.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-Q1TC;
Resistance thermometer input, E5GN-Q1P OMRON Non contact temperature sensor.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function OMRON Non contact temperature sensor.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks OMRON Non contact temperature sensor.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV ES1-LP3.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs OMRON ES1-LP3.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.