LK Automation Limited
Home >> Products >> OMRON >> Master slave station products >> CompoBus/S >> OMRON SRM1-C02-V2 OMRON SRM1-C02-V2

OMRON SRM1-C02-V2 OMRON SRM1-C02-V2

Brand: OMRON
Name: Master control unit
Model: SRM1-C02-V2
Independent type, the function of the built-in controller is not RS-232C, the maximum 256 points.

Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON SRM1-C02-V2.
A wide variety of CompoNet Slave Units,
contribute to system size reduction SRM1-C02-V2
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. I/O classification: Digital I/O.
Internal I/O circuit common: PNP (+ common) OMRON SRM1-C02-V2.
I/O points: 16.
I/O connection method: M3 terminal block.
Models with 3-tier Terminals (16 Points),
Added to the Remote I/O Terminal Series.
Six Models are Available Depending on the,
NPN or PNP Configuration, Input Points,
I/O Points, or Output Points.
Incorporates easy-to-wire terminals each,
connecting to a single wire.
Reduces designing and wiring effort.
Incorporates a removable circuit block of cassette construction OMRON SRM1-C02-V2. Specifications: Input, NPN (+ common), 16 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector OMRON Master control unit.
Rated I/O power supply voltage: Supplied from the communications connector.
Environment-resistive (IP67) I/O.
Terminals with Troubleshooting.
Functions such as Sensor Power OMRON Master control unit.
Supply Short-circuit Detection.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities.
High degree of environmental resistance with dust-proof,
and drip-proofconstruction.
Power supply wiring is not required for input devices OMRON Master control unit.
Connect heavy-load devices (up to 1.5 A).
Power supply wiring is not required for input devices such as sensors.
(Power supply wiring is required for output devices.)
Detects ground faults or disconnects and notifies the Master.
Analog I/O terminal with screw terminal,
block for EtherCAT communicaitons.
The input/output range can be easily,
changed by the setting with the switch.
Detachable screw terminal block,
facilitates the maintenance.
Moving average calculation ffunction SRM1-C02-V2.
Settings within the range of 100μs-64ms.
(For input only.)
Disconnection detection function.
(For input only and for usage with,
1-5V or 4-20mA ranges.)
Selectable node address setting methods:
setting with rotary,

switch and with tool software OMRON SRM1-C02-V2.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.