I/O classification: Input.
Internal I/O circuit common: PNP (– common).
I/O points: 16.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
(Long-distance/High-speed Communications Selection).
(W x H x D) mm for 16-point terminals.
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported.
Name: Screw Terminal Block with SSR Outputs.
Specifications: Outputs;
8 outputs; SSR.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON SRT2-ID16-1.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site
SRT2-ID16-1
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: I/O, NPN (input: + common, output: - common), 16 inputs/16 outputs.
I/O connections: MIL connector OMRON SRT2-ID16-1.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
First Board-type Terminals for Smart Slaves!
Easily modified to handle an array of I/O interfaces,
and eliminates much on-site wiring.
User boards attach easily to the DRT2-@D32BV(-1) using screws. Internal I/O common: PNP.
I/O indicators: LED display (yellow) OMRON SRT2-ID16-1.
Unit power supply current consumption:
80 mA max. (for 20.4 to 26.4-VDC power supply voltage)
Weight: 190 g max.
Expansion functions: No.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications OMRON Transistor Remote I/O Terminals.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected OMRON Transistor Remote I/O Terminals.
(One expansion unit per one I/O terminal unit.)
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance OMRON Transistor Remote I/O Terminals. Name: Bit Slave Units with e-CON Connectors.
Specifications: Outputs; 2 outputs; PNP.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribution.
The I/O power supply is supplied from the communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection SRT2-ID16-1.
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O short circuits OMRON SRT2-ID16-1.
Simple communications connections,
with flat cable and connectors.
Bit-level distribution to support,
essentially any application.