Mounted Connector: MR Plugs.
No. of poles: 34.
Dimension A: 128.
Dimension B: 100.
Mounted Connector model: MR-34RMD2 *3.
Cable Connector model: MR-34F*3.
Conversion Units.
control panels and automatic equipment.
Fallout prevention for terminal screws.
Round or forked crimp terminals can be used.
Mount to DIN Track or via screws.
during DIN Track attachment and removal.
Terminal cover can be locked open.
of five to simplify counting terminal numbers.
Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage OMRON XW2D-34Y6.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
XW2D-34Y6
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON XW2D-34Y6. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Power ratings: 240 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 24 V.
Output current *1: 10 A OMRON XW2D-34Y6.
Cost-effective Single Phase Power Supply.
Universal input and Safety standards.
for worldwide applications.
Space-saving Compact Design.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC.
Operation temperature range: –25 to 60 °C.
Compact Dimension for small space OMRON Slim Connector-Terminal Block Conversion Units.
Flexible installation by special mounting brackets.
Safety standards:
UL508/60950-1, CSA C22 OMRON Slim Connector-Terminal Block Conversion Units. 2 No.107.1/60950-1.
EN50178, EN60950-1.
EMS: Conform to EN61204-3.
EMI: EN55011 Class A.
Three years Warranty. Pitch: 27.5 mm.
Applicable models: PYF14S.
Insulation color: Blue.
A Wide Variety of Square and,
Round Sockets in Front-mounting,
and Back-mounting Models,
Models available with finger protection OMRON Slim Connector-Terminal Block Conversion Units.
Hold-down Clips and Socket Bridges for PYF Sockets,
are also available.
New screwless models available. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control XW2D-34Y6.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads OMRON XW2D-34Y6.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).