Category: incidental cover type.
Structure: DIN guide rail mounting type.
Capacity: 15W.
Output voltage: 5V.
Output current: 3A.
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
Power failure detection function with built-in hint output voltage abnormity.
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Shape: with short lock (with open end cap).
Pole number: 10.
Pole pole number: 1.
Minimum packing unit: 90.
Printed board connector core, MIL specification standard.
Through the use of new productivity design, high reliability and low price synchronization.
A box type plug (XG4C) which is convenient for saving space is provided in the province OMRON S8VM-01505CD.
A press type plug (XG4E) capable of using the relay is provided
S8VM-01505CD
Will be the company''s loose wire connector (XG5) - specific plug (XG8) and PCB type.
(XG2) combined use of various types of packaging can be achieved.
Suitable for the company''s own development of a simple locking lever can make the unique plug (XG8) and,
Box type plugs (XG4C) can also be locked OMRON S8VM-01505CD.
MIL specification (MIL-C-83503) standard.
Standard product conforms to the UL specification (No. E103202 File) certified products. Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.048 A; 60 Hz, 0.041 A .
Rated input: 50 Hz, 7 W ; 60 Hz, 6 W .
Rated rotational speed: 50 Hz, 2600 r/min; 60 Hz, 3000 r/min OMRON S8VM-01505CD.
Maximum flow rate: 50 Hz, 0.6 m3/min; 60 Hz, 0.7 m3/min.
Maximum static pressure: 50 Hz, 39.2 Pa; 60 Hz, 53.9 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 36 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment OMRON Switching Mode Power Supply.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series OMRON Switching Mode Power Supply.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics OMRON Switching Mode Power Supply. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phaase control, and cyclic control S8VM-01505CD.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads OMRON S8VM-01505CD.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).