LK Automation Limited
Home >> Products >> OMRON >> Master slave station products >> CompoBus/S >> SRT2-OD08-1 OMRON SRT2-OD08-1

SRT2-OD08-1 OMRON SRT2-OD08-1

Brand: OMRON
Name: Transistor Remote I/O Terminals
Model: SRT2-OD08-1
I/O classification: Output.
Internal I/O circuit common: PNP (+ common).
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported.

Unit: Terminal block model.
I/O classification: Digital output.
Internal I/O common: NPN (- common).
I/O points: 16.
I/O connections: M3 terminal board.
Power supplyvoltage: 24 VDC.
I/O specification: 0.5 A, DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available OMRON SRT2-OD08-1.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires SRT2-OD08-1
DIN track mounting. Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON SRT2-OD08-1.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON SRT2-OD08-1. Input type: Thermocouple input.
I/O points: 4 inputs allocated 4 input words at the Master Unit,
(8 input words allocated when 1/100 display mode is selected).
Temperature Input Terminal with Smart Functionality OMRON Transistor Remote I/O Terminals.
The Temperature Input Terminal can be used with almost the same functionality as a.
Analog Input Terminal, such as with scaling and comparator functions OMRON Transistor Remote I/O Terminals.
Enhanced performance is provided with functionality specific to the Temperature,
Input Terminal, such as the recording the operating time in a preset temperature,
range and temperature difference detection between input channels. Specifications: Inputs, NPN (+ common), 4 points OMRON Transistor Remote I/O Terminals.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications. connector.
Rated I/O power supply voltage: 24 VDC.
Remote I/O Terminals with High.
Degree of Environmental Resistance.
(IP67) in Product Lineup Including.
Economical Input, Output, and Mixed I/O Models.
Common Smaart Slave functionality provides strong support for equipment,
operation status monitoring and effective maintenance SRT2-OD08-1.
High degree of environmental resistance with dust-proof and drip-proof,
construction. (IP67)
Models with one cconnector for two outputs are available to make easier,
connection with hydraulic valve devices OMRON SRT2-OD08-1.
(Models with 16 outputs and models with 16 mixed I/O)


...More relevant models >>>>