SRT2-ID08 OMRON SRT2-ID08 Transistor Remote I/O Terminals

Brand: OMRON
Name: Transistor Remote I/O Terminals
Model: SRT2-ID08
I/O classification: Input.
Internal I/O circuit common: NPN (+ common).
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported.

I/O classification: Input and output.
Internal I/O circuit common: NPN (input: + common; output – common).
I/O points: 32.
I/O connection method: MIL connector.
Rated voltage for communications power supply: 24 VDC.
Rated voltage for I/O power supply: 24 VDC.
Applicable relay: G3DZ-2R6PL.
Subminiature 32-point Remote Terminal with Connectors OMRON SRT2-ID08.
Compact dimensions: 35 × 60 × 80 (W × D × H) SRT2-ID08
Long-distance and high-speed communications modes available.
Downsizing enabled with 32-point MIL connector for I/O connection. Classification: Analog Output Terminal.
I/O points: 1 or 2 (selectable with DIP switch).
Compact Analog Output Model is the,
Same Shape as 16-point Remote I/O Terminals OMRON SRT2-ID08.
Two output points or 1 output point is selectable.
Resolution: 1/6,000.
105 x 48 x 50 (W x H x D). I/O classification: Temperature inputs.
I/O points: 4 inputs.
I/O connections: Terminal block.
Power supply voltage: 24 VDC.
Input specification: Platinum resistance thermometer.
Temperature Input Units for use with MULTIPLE I/O TERMINAL.
Four inputs.
Thermocouples and platinum resistance thermometer models,
are available OMRON SRT2-ID08.
Conversion time is only 250 ms for 4 inputs.
The Configurator can be used to calibrate temperatures.
The circuit section can be removed, so rewiring isn’t,
required during maintenance.
DIN track mounting. Name: Slice I/O Units; Temperature Input OMRON Transistor Remote I/O Terminals.
(Resistance Thermometers).
Specifications: Temperature input,
(Resistance thermometer:Pt1000) 2 points.
Standards: CE, UC1, L OMRON Transistor Remote I/O Terminals.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON Transistor Remote I/O Terminals.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: Inputs;;
NPN (+ common); 32 points SRT2-ID08.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Termminals OMRON SRT2-ID08.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H).