LK Automation Limited
Home >> Products >> MITSUBISHI >> Ans/QnAs series PLC >> Other function modules
MITSUBISHI
Reader module
A1SJ71ID1-R4


AnS, QnAS bus connection, the reader to write program 1 channel connection.
MITSUBISHI
Reader module
A1SJ71ID2-R4


AnS, QnAS bus connection, the reader to write program 2 channel connection.
MITSUBISHI
Modular
A1SJ71AS92


The main unit of the AS-i system The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it, Lag time, this is the time constant of the input circuit, The time constant of the output circuit, the arrangement of the user statement and the use of the instruction, The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on. This phenomenon is called the I/O delay time effect.
MITSUBISHI
Modular
A1SJ71B62-S3


Signal transmission device B/NET interface device for power distribution control equipment The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it, Lag time, this is the time constant of the input circuit, The time constant of the output circuit, the arrangement of the user statement and the use of the instruction, The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on. This phenomenon is called the I/O delay time effect.
MITSUBISHI
Modular
A1SJ72J95


JEMANET (OPCN-1) interface unit from the station. The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it, Lag time, this is the time constant of the input circuit, The time constant of the output circuit, the arrangement of the user statement and the use of the instruction, The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
MITSUBISHI
Modular
A1SJ71J92-S3


JEMANET (OPCN-1) interface unit master station. The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it, Lag time, this is the time constant of the input circuit, The time constant of the output circuit, the arrangement of the user statement and the use of the instruction, The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
MITSUBISHI
Main communication module
A1SJ51T64


Up to controlled I/O points: 8 point I/O combination module, up to 128 points. Use any I/O module, up to 64 points.
MITSUBISHI
ME-NET module
A1SJ71ME81


ME-NET interface unit Structured text language is a programming language that describes a program with a structured description of the text. It is a programming language similar to a high level language.