LK Automation Limited
Home >> Products >> MITSUBISHI >> MITSUBISHI Ans/QnAs series PLC
MITSUBISHI
Intelligent communication module
A1SD51S


A1SD51S is an intelligent communication module used in ANS series, Can use the AD51H-BASIC language to make online or offline programming on the universal terminal or computer, Multitasking can also be performed with up to two programs at high speed. PLC is the use of " sequential scanning, and constantly circulating " way to work.
MITSUBISHI
CC-Link module
A1SJ61BT11


Three remote components can be connected to the CC-LINK system. Remote I/O: refers to the field components that require only ON/OFF control, Such as digital I/O or pneumatic valve, etc.
MITSUBISHI
Modem module
A1SJ71CMO-S3


Using a modem middle modular connector unit faces to transmit data transmission speed: 0.3-14.4kbps.
MITSUBISHI
CC-Link module
A1SJ61QBT11


CC-Link master / slave station. PLC is the use of " sequential scanning, and constantly circulating " way to work.
MITSUBISHI
Reader module
A1SD35ID1


Reader writer 1 channel connection, AnSCPU/QnASCPU. PLC is the use of " sequential scanning, and constantly circulating " way to work.
MITSUBISHI
Reader module
A1SD35ID2


Reader writer 2 channel connection, AnSCPU/QnASCPU. PLC is the use of " sequential scanning, and constantly circulating " way to work.
MITSUBISHI
Reader module
A1SD32ID1


AnS, QnAS bus connection, the reader to write program 1 channel connection. Input status and input information input from the input interface, CPU will be stored in the working data memory or in the input image register.
MITSUBISHI
Reader module
A1SD32ID2


AnS, QnAS bus connection, the reader to write program 2 channel connection. Input status and input information input from the input interface, CPU will be stored in the working data memory or in the input image register.
MITSUBISHI
Reader module
A1SJ71ID1-R4


AnS, QnAS bus connection, the reader to write program 1 channel connection.
MITSUBISHI
Reader module
A1SJ71ID2-R4


AnS, QnAS bus connection, the reader to write program 2 channel connection.
MITSUBISHI
Modular
A1SJ71AS92


The main unit of the AS-i system The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it, Lag time, this is the time constant of the input circuit, The time constant of the output circuit, the arrangement of the user statement and the use of the instruction, The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on. This phenomenon is called the I/O delay time effect.
MITSUBISHI
Modular
A1SJ71B62-S3


Signal transmission device B/NET interface device for power distribution control equipment The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it, Lag time, this is the time constant of the input circuit, The time constant of the output circuit, the arrangement of the user statement and the use of the instruction, The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on. This phenomenon is called the I/O delay time effect.
   22 Results    Page: [ First page] << Previous page 15 16 17 18 19 20 21 22 next page >>