A1SD70 Manual MITSUBISHI A1SD70 Hardware User's Manual

Product model: A1SD70
Name: Positioning Module
Brand: MITSUBISHI
Sort: Hardware User's Manual
File language: English
File size: 0.94MB
Input type: DC input, negative public end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/6mA.
External connection: 3 wire.
Spring clamping terminal platform push type input module.
Input module with diagnostic function
The use of push type, do not need screw fastening, so can reduce the wiring hours MITSUBISHI A1SD70 User's Manual.
Can be used for each 1 points to enter the wiring of the broken wire detection A1SD70
Wiring abnormality of external power supply can be confirmed.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. Input points: 16 points.
Voltage: AC200 ~ 240V.
Current: 10mA MITSUBISHI A1SD70 User's Manual.
Response time: 25ms.
16 points / a common end..
20 point terminal station.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive MITSUBISHI A1SD70 User's Manual.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of thee component image register are changed with the change of the execution of the program A1SD70 Manual.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to thhe adoption of centralized sampling A1SD70 Manual.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
Related products
MITSUBISHI
High speed counting module
A1SD62E
MITSUBISHI High speed counting module A1SD62E
2 channels. 200/10kpps. Count input signal: D
MITSUBISHI
Analog input / output module
A1S63ADA
MITSUBISHI Analog input / output module A1S63ADA
Input channel numer: 2. Output channel nume
MITSUBISHI
Extension cable
A1SC07NB
MITSUBISHI Extension cable A1SC07NB
Cale length: 0.7 meters Extending cale to c