LK Automation Limited
Home >> Products >> MITSUBISHI >> Ans/QnAs series PLC >> MELSECNET/10 module >> A1SJ71QE71-B2 MITSUBISHI Network module MITSUBISHI A1SJ71QE71-B2

A1SJ71QE71-B2 MITSUBISHI Network module MITSUBISHI A1SJ71QE71-B2

Brand: MITSUBISHI
Name: Network module
Model: A1SJ71QE71-B2

Output type: relay.
Output points: 16 points.
Load voltage: AC120/DC24.
Load current: 2A.
Connection mode: terminal row.
Common public end points: 8.
Sequential function flow chart language is designed to satisfy the sequential logic control.
The process of sequential process action is divided into steps and transformation conditions,
According to the transfer condition, the control system is distributed in the function flow sequence,
Step by step according to the sequence of actions MITSUBISHI A1SJ71QE71-B2 A1SJ71QE71-B2
Each step represents a control function, represented by the box.
In the box, the ladder logic is used to complete the task of the corresponding control function.
This programming language makes the program structure clear and easy to read and maintain,
Greatly reduce the programming workload, shorten the programming and debugging time MITSUBISHI A1SJ71QE71-B2.
Used in the system of the size of the school, procedures for more complex occasions.
Sequence function flow chart programming language features: to function as the main line, in accordance with the functional flow of the order of distribution, clear, easy to understand the user program,
Avoid the defect of ladder diagram or other languages,
At the same time, the use of ladder language to avoid the use of ladder programming,
Due to the complicated mechanical interlock, the structure of the user program is complex and difficult to understand,
User program scan time is also greatly reduced MITSUBISHI A1SJ71QE71-B2 MITSUBISHI Network module. Program memory capacity: 8k.
Input / output points: maximum 256 points MITSUBISHI Network module.
A scan cycle of PLC must pass through three stages: input sampling, program execution and output refresh.
PLC in the input sampling phase: first of all, in order to scan the sequence of all existing input latches in the input terminal of the state or input data read,
And write it into the corresponding input status register,
Refresh the input, then close the input port, enter the program execution stage MITSUBISHI Network module. Signal transmission device B/NET interface device for power distribution control equipment
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
This phenomenon is callled the I/O delay time effect A1SJ71QE71-B2.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CCPU MITSUBISHI A1SJ71QE71-B2.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive.