CC-Link master / local station.
Transmission speed: 10Mbps.
Remote input / output: 8192 points.
Remote register: 2048 words.
Link points in Ver.2.0 CC-Link master station.
Using CC-Link to connect with multiple devices.
Rich device using open network CC-Link,
System can be constructed according to the control requirements L02SCPU-P Manual .
Support Ver.2.0 CC-Link,
So it can be effectively used in the field of large capacity data communication
L02SCPU-P
No need to set the transmission speed of the local station
Automatic tracking function of transmission speed
When used as a local station, the transmission speed of the master station can be automatically tracked,
Do not need to set up in the local station.
The transmission speed of the operation can be confirmed by the positive LED of the module L02SCPU-P Manual . Number of input channels: 8ch.
Input current: DC0 ~ 20mA.
Conversion speed: 1ms/ch.
Resolution: 1/8000.
By shifting the function easily when the system starts to fine tune the movement function.
Shift the set value to (shift to) the function of the digital output value.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup L02SCPU-P Manual .
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal detection function of the input signal which is outside the range of the set range MITSUBISHI Programmable Controller Manual MITSUBISHI Programmable Controller Manual .
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter range extension
Range of scalable input range.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected MITSUBISHI Programmable Controller Manual . Input points: 16 points.
Rated input voltage: AC100 ~ 120V.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the parrt can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on L02SCPU-P Manual L02SCPU-P Programming Guide.