MITSUBISHI Q02UCPU Programming Manual Q02UCPU MELSAP-L Manual

Product model: Q02UCPU
Name: CPU
Brand: MITSUBISHI
Sort: MELSAP-L Programming Manual
File language: English
File size: 1.76MB
Module connector 1Ch.
1ch RS-232.
The possibility of expanding control with intelligent function.
Providing a variety of analog modules, is the ideal choice for process control applications.
Can also meet the needs of high speed, high precision control.
Most suitable analog modules for high speed conversion control Q02UCPU Programming Manual.
Can provide a variety of analog and digital analog conversion module products Q02UCPU
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings Q02UCPU Programming Manual. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.RS232 cable for connecting cables and 3M, CPU.4 channel.
Input: DCO~20mA DC-10~10V Q02UCPU Programming Manual.
Output (resolution): 0~32000; -32000~32000; 0~64000; -64000~64000.
Conversion speed: 10ms/4 channel.
18 point terminal station.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.1 axes, open collector output type.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Maximum pulse output: 200Kpps.
40 pin connector.
Positioning module.
Open collector output.
Differential driver output.
Based on the usee of open collector outputs and differential drive output type 2 types Q02UCPU Manual.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control Q02UCPU Manual.
(the command pulse of the open collector positioning module is highest 200kpps.)
Related products
MITSUBISHI
CPU unit
Q4ARCPU
MITSUBISHI CPU unit Q4ARCPU
Input and output points: 4096 points. Input /
MITSUBISHI
General high speed CPU
Q04UDVCPU
MITSUBISHI General high speed CPU Q04UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
Moving CPU unit
A73CPU
MITSUBISHI Moving CPU unit A73CPU
Multi axis positioning controller. Program ca
MITSUBISHI
Programmable logic controller CPU
R16CPU
MITSUBISHI Programmable logic controller CPU R16CPU
Operation control mode: stored procedure repe