PCI bus.
Support Japanese, English OS.
GI optical cable.
Dual loop controller network (control station / common station).
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) MITSUBISHI Q02CPU-A Manual.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of
Q02CPU-A
Even if the information reaches saturation, it will not affect the link scan time.
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability MITSUBISHI Q02CPU-A Manual.
The transmission distance of 50m/200m/1km/3km can be selected.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines.Output points: 4 points (select the source type + drain type), 2 points (select the source type + source).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V MITSUBISHI Q02CPU-A Manual.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down. Express PCI bus.
Support japanese.
Ethernet cable.
Linear / star (linear and star can be mixed use)
Field network (control station / common station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) Q02CPU-A Programming Manual.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmmission) communication separately, so as to ensure the timeliness of Q02CPU-A Programming Manual.
Even if the information reaches saturation, it will not affect the link scan time.