LK Automation Limited
Home >> Download >> OMRON >> Catalog Download >> K3HB-XVD-FLK1AT11 AC100-240 PDF datasheet OMRON K3HB-XVD-FLK1AT11 AC100-240 datasheet PDF catalog

K3HB-XVD-FLK1AT11 AC100-240 PDF datasheet OMRON K3HB-XVD-FLK1AT11 AC100-240 datasheet PDF catalog

Product model: K3HB-XVD-FLK1AT11 AC100-240
Name: Voltage and current panel meter
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 1.90MB
Type of input: AC current input.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with OMRON K3HB-XVD-FLK1AT11 AC100-240 PDF catalog.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-XVD-FLK1AT11 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DevTime specification: Instantaneous type OMRON K3HB-XVD-FLK1AT11 AC100-240 PDF catalog.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase OMRON K3HB-XVD-FLK1AT11 AC100-240 PDF catalog.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Control supply voltage: 200 VAC; With voltage fluctuation compensation.
Operating current: 8 to 20 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if onne heater el,
ement among several heater elements has been burned out K3HB-XVD-FLK1AT11 AC100-240 PDF datasheet.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters K3HB-XVD-FLK1AT11 AC100-240 PDF datasheet.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.
Related products
OMRON
Voltage and current panel meter
K3HB-XVD-FLK1AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XVD-FLK1AT11 AC100-240
Input type: DC voltage input type. Output ty
OMRON
Rotating pulse meter
K3HB-RPB-FLK3AT11 AC100-240
OMRON Rotating pulse meter K3HB-RPB-FLK3AT11 AC100-240
Input type: PNP input type. Event input term
OMRON
Rotating pulse meter
K3HB-RPB-L2AT11 AC100-240
OMRON Rotating pulse meter K3HB-RPB-L2AT11 AC100-240
Input type: PNP input type. Event input term