Models: UVR+OVR.
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular K3HB-XVD-FLK3AT11 Manual.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system
K3HB-XVD-FLK3AT11
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries K3HB-XVD-FLK3AT11 Manual.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring K3HB-XVD-FLK3AT11 Manual. Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or NPN input.
Output type: Judgement output, 2 relay contact outputs (SPST-NO) Normally energized relays (See note.);
Data transmission output, DC current (0 to 20 mA, 4 to 20 mA) OMRON K3HB-XVD-FLK3AT11 Communications Manual.
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D) OMRON K3HB-XVD-FLK3AT11 Communications Manual.
Multi-input compatible: DC voltage/current, rotary pulse.
Two display colors (switchable): green/red.
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66). Ideal for current monitoring for,
industrial facilities and equipment OMRON K3HB-XVD-FLK3AT11 Communications Manual.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startupp lock and operating time can be set separately K3HB-XVD-FLK3AT11 .
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and coommercial CT input,
(0 to 1 A or 0 to 5 A) supported K3HB-XVD-FLK3AT11 Manual.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.