K3HB-XVA-FLK3AT11 Manual OMRON K3HB-XVA-FLK3AT11 Communications Manual

Product model: K3HB-XVA-FLK3AT11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 2.07MB
Function: Phase sequence and phase loss monitoring.
Rated input voltage: 3-phase, 3-wire 200 to 480 VAC.
Relay output: DPDT ×1.
Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Greater resistance to inverter noise.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON OMRON K3HB-XVA-FLK3AT11 Communications Manual.
Supports phase loss detection when the motor is operating K3HB-XVA-FLK3AT11
5 A (resistive load) at 250 VAC, DPDT x 1.
Output status can be monitored using LED indicator.
Ideal to prevent reverse operation of motors. Type of input: AC voltage input.
Output type: no output.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V OMRON K3HB-XVA-FLK3AT11 Communications Manual.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations OMRON K3HB-XVA-FLK3AT11 Communications Manual.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
ULTime specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated fromm the start of operation K3HB-XVA-FLK3AT11 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XVA-FLK3AT11 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Time interval table
K3HB-PNB-FLK3AT11 AC/DC24V
OMRON Time interval table K3HB-PNB-FLK3AT11 AC/DC24V
Input type: NPN/ voltage pulse input type. E
OMRON
Voltage and current panel meter
K3HB-XVA-T11 AC100-240
OMRON Voltage and current panel meter K3HB-XVA-T11 AC100-240
Type of input: AC voltage input. Output type
OMRON
Voltage and current panel meter
K3HB-XAA-FLK3AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XAA-FLK3AT11 AC/DC24
Type of input: AC current input. Output type