Display type: UP display timer (increments form 0 to the set time).
Output type: Contact output (SPDT).
Pin type: 8-pin.
Memory backup: Not provided.
Supply voltage: 100 to 240 VAC, 12 to 48 VDC.
Rated time: 1 min to 99 h 59 min(See note 3.).
Miniature DIN-sized (48 x 48 mm) Quartz.
Timer with Abundant Series Versions OMRON SYSMAC REFERENCE MANUAL.
Series version cover a wide range of rated times; 9
H8PS-8BFP999 s,
99.99 s, 999.9 s, 99 min 59 s, and 99 hrs 59 min.
Selection of elapsed time indication, remaining time indication,
contact output, and transistor output types to suit requirements.
Power supply freely selectable within a range of 100 to,
240 VAC, as well as 12 to 48 VDC.
Certified for UL and CSA safety standards OMRON SYSMAC REFERENCE MANUAL. Count input: PNP/NPN universal DC voltage input(4.5 to 30 VDC).
Max. counting speed: 30 Hz ←→ 1 kHz(switchable).
Display: 7-segment LCD.
Model: Light-gray body.
Eight-digits, counting range 0 to 99999999.
Dual input speed: 30 Hz ←→ 1 kHz,
(except for AC/DC multivoltage input models). Number of outputs: 8 outputs.
Mounting method: Surface mounting/track mounting.
Output configuration: NPN transistor output OMRON SYSMAC REFERENCE MANUAL.
Bank function: No.
This Compact Cam Positioner, Popular for Its.
Ease-of-use, Now Comes with Even Better Functions.
Compact 8-, 16-, and 32-output Models available that,
are 1/4-DIN size at 96 x 96 mm H8PS-8BFP REFERENCE MANUAL.
High-speed operation at 1,600 r/min and high-precision settings,
to 0.5° ensure widespread application.
Highly visible display with backlit negative transmissive LCD H8PS-8BFP REFERENCE MANUAL.
Advance angle compensation function to compensate for output delays.
Bank function for multi-product production (8 banks).
(H8PS-16@/-32@ models.).
Speed display and pulse output.
Approved standards: UL/CSA and EMC. Type: H5CX-A series.
Time specifications: 0 H8PS-8BFP REFERENCE MANUAL. 001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-dduty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H8PS-8BFP Manual.
External connections: 11-pin socket.
Input: Signall, Reset, Gate (NPN/PNP input) OMRON SYSMAC REFERENCE MANUAL.
Output: Transistor output(SPST).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry.