OMRON K3HB-PNB-FLK3AT11 Manual K3HB-PNB-FLK3AT11 Communications Manual

Product model: K3HB-PNB-FLK3AT11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 1.85MB
Control supply voltage: 110/220 VAC; Without voltage fluctuation compensation.
Operating current: 0.5 to 1 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K3HB-PNB-FLK3AT11 Communications Manual.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out K3HB-PNB-FLK3AT11
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage K3HB-PNB-FLK3AT11 Communications Manual. Rated primary current: 100 A.
Rated secondary current: Special output.
Installation: Installed separately.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously K3HB-PNB-FLK3AT11 Communications Manual.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase conntrol, and cyclic control K3HB-PNB-FLK3AT11 Manual.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-PNB-FLK3AT11 Manual.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Rotating pulse meter
K3HB-RNB-FLK3AT11 AC/DC24V
OMRON Rotating pulse meter K3HB-RNB-FLK3AT11 AC/DC24V
Input type: NPN/ voltage pulse input type. E
OMRON
Temperature panel
K3HB-HTA-FLK3AT11 AC/DC24
OMRON Temperature panel K3HB-HTA-FLK3AT11 AC/DC24
Type of input: platinum resistance / thermoco
OMRON
Time interval table
K3HB-PNB-FLK3AT11 AC/DC24V
OMRON Time interval table K3HB-PNB-FLK3AT11 AC/DC24V
Input type: NPN/ voltage pulse input type. E
OMRON
Time interval table
K3HB-PNB-A-DRT1 AC100-240
OMRON Time interval table K3HB-PNB-A-DRT1 AC100-240
Input type: NPN/ voltage pulse input type. E