An Ideal Indicator for OK/NG Judgements in Automated and,
Picking Machines, Measuring Factors such as Pressure,
Load, Torque, and Weight Using Load Cell Signal Input.
Easy recognition of judgement results using color display that can be switched,
between red and green.
Equipped with a position meter for monitoring operating status trends K3HB-XVA-1 Communications Manual.
External event input allows use in various measurement and discrimination, applications
K3HB-XVA-1
Input 0.001 mVDC or higher (0.000 to 19.999 mV range supported).
External power takeoff of 100 mA at 10 VDC provided. (Models with 5-VDC,
power takeoff also available.).
Series expanded to include DeviceNet models.
Short body with depth of only 95 mm (from behind the front panel), or 97 mm,
for DeviceNet models K3HB-XVA-1 Communications Manual.
UL certification approval (Certification Mark License).
CE Marking conformance by third party assessment body.
Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66).
Capable of high-speed sampling at 50 times per second (20 ms).
• Easy-to-set two-point scaling allows conversion and display of any,
user-set values. Product: 500-mm Conductive Urethane Tube K3HB-XVA-1 Communications Manual.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 8 to 20 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Transistor: -; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power suupply voltage: AC/DC24V K3HB-XVA-1 Manual.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range off pulse interval time K3HB-XVA-1 Manual.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurable