Name: Two-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction CP1E-N14DT-A PROGRAMMING MANUAL
CP1E-N14DT-A
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Model: C200HW-PA204S.
Supply voltage: 100 to 120 VAC, 200 to 240 VAC.
Comments: With 24-VDC service power supply CP1E-N14DT-A PROGRAMMING MANUAL. NO. OF I/O SLOTS: 6 SLOTSName: Temperature Control Module.
Model: C200H-TC002.
Sensor: Thermocouple: R, S, K(CA), J(IC), T(CC), E(CRC), B, N, L(IC), U(CC).
Control output: Voltage output.Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CP1E-N14DT-A PROGRAMMING MANUAL.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Model: C500-CPU11-EV1.
C500-CP CPU CPU MODULE JAPANESE C500-CPU11-EV1I/O Cable (for I/O to Interface Racks) 30 m (L) CV500-CN322I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 60K steps.
Data memory capacity: 128K words (DM: 32K words, EM: 32K words ×3 banks).Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacce compared,
with previous systems CP1E-N14DT-A Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1E-N14DT-A Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.