OMRON K2CM-Q2M Manual K2CM-Q2M Communications Manual

Product model: K2CM-Q2M
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 0.29MB
Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K2CM-Q2M Communications Manual.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K2CM-Q2M
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2CM-Q2M Communications Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K2CM-Q2M Communications Manual.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event inputType of input: AC current input.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equippeed with K2CM-Q2M Manual.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub ppressure gauge for monitoring the operation trend K2CM-Q2M Manual.
External event input can be applied to a variety of measurement and identification situations.
Devi
Related products
OMRON
Motor Protective Relay
K2CM-1L
OMRON Motor Protective Relay K2CM-1L
Time specification: Inverse type. Current set
OMRON
Motor Protective Relay
K2CM-Q4LA
OMRON Motor Protective Relay K2CM-Q4LA
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-Q4HA
OMRON Motor Protective Relay K2CM-Q4HA
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-Q2MAV
OMRON Motor Protective Relay K2CM-Q2MAV
Time specification: Instantaneous type. Curre