Product model: K3HB-XVD-FLK3AT11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 2.07MB
Input type: PNP input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V OMRON Digital Temperature Controllers Communications Manual.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K3HB-XVD-FLK3AT11
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurablePower supply voltage: 100 to 240 VAC OMRON Digital Temperature Controllers Communications Manual.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload OMRON Digital Temperature Controllers Communications Manual.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement K3HB-XVD-FLK3AT11 Communications Manual.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads K3HB-XVD-FLK3AT11 Communications Manual.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K3HB-XVD-FLK3AT11 Communications Manual.
External power supply DC12V80mA.
Output type: relay contact; PASS1c; HH, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed, high precision measurement, deteermine the color display,
Can switch the green / Red 2 kinds of display colors K3HB-XVD-FLK3AT11 Manual.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be appliied to a variety of measurement and identification situations OMRON Digital Temperature Controllers Communications Manual.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
UL standard
Related products
OMRON
Voltage and current panel meter
K3HB-XVD-FLK3AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XVD-FLK3AT11 AC/DC24
Input type: DC voltage input type. Output ty
OMRON
Voltage and current panel meter
K3HB-XVD-FLK1AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XVD-FLK1AT11 AC/DC24
Input type: DC voltage input type. Output ty
OMRON
Temperature panel
K3HB-HTA-FLK3AT11 AC/DC24
OMRON Temperature panel K3HB-HTA-FLK3AT11 AC/DC24
Type of input: platinum resistance / thermoco
OMRON
Voltage and current panel meter
K3HB-XAD-FLK3AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XAD-FLK3AT11 AC100-240
Input type: DC current input. Output type: c