Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V K3HB-XVD-L1AT11 .
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified
K3HB-XVD-L1AT11
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trendSetting range: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC K3HB-XVD-L1AT11 .
Power supply voltage: 24 VAC/DC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 5 A at 250 VAC (resistive load) K3HB-XVD-L1AT11 .
Output relay can be switched between normally open and normally closed.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Type: Medium-sensitivity models.
Sensed current: 200 mA/500 mA(switchable).
Type: Delayed models.
Operating time: 0.3/0.8 s (switchable).
Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of insulation in,
electrical devices.
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutually compatible.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease. Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: linear; current; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speedd, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors K3HB-XVD-L1AT11 Communications Manual.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations K3HB-XVD-L1AT11 Communications Manual.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.