LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> Programmable Terminals CPM1A-20CDR-A-V1 HOST CONNECTION MANUAL OMRON CPM1A-20CDR-A-V1 Manual

Programmable Terminals CPM1A-20CDR-A-V1 HOST CONNECTION MANUAL OMRON CPM1A-20CDR-A-V1 Manual

Product model: CPM1A-20CDR-A-V1
Name: Programmable Terminals
Brand: OMRON
Sort: HOST CONNECTION MANUAL
File language: English
File size: 1.49MB
Model: C200HW-PA204.
Supply voltage: 100 to 120 VAC, 200 to 240 VAC.
Comments: ---.C1000H-CP CPU 62 k words 1024 pts C1000H-CPU01-V1.Data Setting Console Connecting Cable, For C200H-DSC01.
4M.Name: e-CON Connectors.
Specifications: Outputs; 8 outputs ; NPN;
Without Short-circuit and,
Disconnected Line Detection CPM1A-20CDR-A-V1 HOST CONNECTION MANUAL.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CPM1A-20CDR-A-V1
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CPM1A-20CDR-A-V1 HOST CONNECTION MANUAL. Unit classifi cation: CS1 CPU Bus Unit.
Product name:Controller Link Unit.
Specifications: Communications cable,
Wired shielded twisted-pair cable;
Communications type, Data links and,
message service; Duplex support, No.
Max. Units mountable per CPU Unit, 8 CPM1A-20CDR-A-V1 HOST CONNECTION MANUAL.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.33A; 26V, --.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an,
FA network that can send,
and receive large amounts,
of data easily and at high speed OMRON CPM1A-20CDR-A-V1 Manual.
The Controller Link supports data,
links that enable sharing data between,
PLCs and computers and a message service,
that enables sending and receiving,
data whenever required OMRON CPM1A-20CDR-A-V1 Manual.
With Wired Controller Link Units,
systems can be flexibly built by using,
Repeater Units to enable T branches,
long-distance wiring, and converting,
part of the network to optical cable OMRON CPM1A-20CDR-A-V1 Manual. Output type: Relay.
Inputs points: 12 points.
Outputs points: 8 points.Model: CPM2C-PA201. Input: 100 to 240 V AC.Output: 24 V DC/600 mA.C500-AS Special I/O Unit ASCII BASIC UNIT C500-ASC01.For 3-slot Backplane.Name: Temperature Sensor Module.
Model: C200H-TS102.
Temperature sensor: RTD (Pt 100 Ω.)(DIN/1989 JIS).
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected).For 10-slot Backplane.Unit type: 10 I/O points 6 inputs; 4 outputs, Connector.
Input: 6 points: 24 VDC.
Output: 4 points: transistor (sinking).
Clock: Yes.
Slaves with the Complex Functionality Needed,
for Distributed Blocks.
Programmable Slaves combine devices, such as sensors and actuators,
into one functional unit that is treated as a DeviceNet slave.
Programmaable Slaves greatly facilitate device distribution,
and functional organization CPM1A-20CDR-A-V1 .
They help standardize programming between units and reduce the amount of,
programming required at the master.
I/O and operattional checks can be performed for each functional unit,
rather than waiting CPM1A-20CDR-A-V1 HOST CONNECTION MANUAL.
for final system assembly, as with conventional distributed I/O systems.
Related products
OMRON
Expansion I/O Module
CPM1A-20EDT1
OMRON Expansion I/O Module CPM1A-20EDT1
Output type: Transistor sourcing. Inputs poin
OMRON
PLC
CPM1A-20CDR-A-V1
OMRON PLC CPM1A-20CDR-A-V1
Power supply: AC power supply. Output method:
OMRON
PLC
CPM1A-20CDT1-D-V1
OMRON PLC CPM1A-20CDT1-D-V1
Power supply: DC power supply. Output method:
OMRON
PLC
CPM1A-30CDR-A-V1
OMRON PLC CPM1A-30CDR-A-V1
Power supply: AC power supply. Output method: