Safety grade (SIL): SIL 3 (IEC 61508).
Performance level (PL): e PL (13849-1 EN/ISO).
Operation control mode: stored procedures repeated operation.
Program capacity: 1200K (security program: 40K).
Program memory: 4800K.
Soft element / tag memory: 3370K.
Data memory: 40M.
Unified program development environment MITSUBISHI AJ35PJ-8S1.
Whether the general control procedures or safety control procedures, can be integrated into 1 Engineering documents,
Unified management by Works3 GX
AJ35PJ-8S1 The troublesome operation can save more than one project file management.
When you create a security control program, you are also the same as when you create a general control program,
Various features of GXWorks3 can be developed using the support program MITSUBISHI AJ35PJ-8S1.
Improve production efficiency through high responsiveness and rich program capacity.
Efficient use of high performance iQ-R CC-Link series and IE Field MELSEC networks,
Improve responsiveness and improve production efficiency.
In addition, the security control program capacity increased to 40K, about 3 times in the past MITSUBISHI AJ35PJ-8S1.
Safe CPU can be used to deal with complex large capacity programs . Input: 4 channels.
Platinum resistance (Pt100; JPt100).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusiion molding macchine,
The temperature regulating module has the function of preventing overheating and preventing over cooling AJ35PJ-8S1.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrroll (heating and cooling) mode AJ35PJ-8S1.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
AJ35PJ-8S1 Operation manual/Instructions/Model selection sample download link: