Input and output points: 40 points.
Power supply: AC100-240V.
Input points: 24 points.
Output points: 16 points.
Output form: transistor output (drain).
Power consumption: 37W.
Weight: 0.7KG.
Outline dimension: 130x90x86mm.
FX3GE on the performance of the FX3GA increased analog input / output and Ethernet communication and other built-in features MITSUBISHI R120PCPU.
Applicable to a wide variety of applications.
Basic unit: 24/40 point
R120PCPU
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost PLC.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points.
A versatile PLC MITSUBISHI R120PCPU.
Built in CPU, power supply, input and output, analog input and output, Ethernet port, can be used immediately after the purchase .
High speed operation.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function. CC-Link (intelligent equipment station) MITSUBISHI R120PCPU.
Twisted pair. Cable length: 0.5M.
Amplifier CC-Link interface unit cable .
For MR-J2S-11KA (4) MR-J2S-22KA to (4).
Amplifier and CC-Link interface unit using 0.5 m (1.64 ft) or shorter cables. 2 channels.
50kpps.
Count input signal: DC5/12/24V.
External input: DC5/12/24V.
Output: Transistor (open collector) 0.5A DC12/24V.
Output: DC12/24V, 0.3A.
47 point terminal station.
How to determine the input / output device of MITSUBISHI plc.
According to the control requirements of the system,
All input devices and output devices required for the determination of the system,
To determine the input / output device related to the MITSUBISHI PLC,
To determine the I/O PLC points.
Detailed analysis of the process and work characteristics of the controlled object,
To understand the coordination between the controlled object machine, electricity and liquid,
The control requirements of the controlled object for MITSUBISHI PLC control system are put forward,
Determine the control prrogram, to deevelop a design task book R120PCPU. Output type: relay output.
Output points: 16 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: AC240V/2mA.
External connection: 2 wire.
Type of input and output termminnal R120PCPU.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.
R120PCPU Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=R120PCPU&select=5