MITSUBISHI CL1Y4-T1B2
Output type: bidirectional thyristor output.
Output points: 16 points.
OFF leakage current: 1.5mA following (AC100V) below /3mA (AC200V).
Output protection function: No.
Rated load voltage / current: AC100V~240V/0.6A.
External connection: 2 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup MITSUBISHI CL1Y4-T1B2.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool CL1Y4-T1B2 2 slots.
Can be installed in the power supply unit for A series units installed QnA/ MITSUBISHI CL1Y4-T1B2.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program .
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage MITSUBISHI CL1Y4-T1B2.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate. Input type: DC input, positive common end.
Input points: 4 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type.
Output points: 4 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DDC24V/0 .5A.
Exxternal connection: 3 line /2 line type CL1Y4-T1B2.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,,
TThe human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool CL1Y4-T1B2.
CL1Y4-T1B2 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=CL1Y4-T1B2&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Screw terminal type output module
CL1Y4-R1B1
MITSUBISHI Screw terminal type output module CL1Y4-R1B1
Output type: relay output. Output points
MITSUBISHI
Screw terminal type output module
CL1Y4-T1B2
MITSUBISHI Screw terminal type output module CL1Y4-T1B2
Output type: transistor output, drain ty
MITSUBISHI
Sensor connection type output module
CL1Y4-T1C2
MITSUBISHI Sensor connection type output module CL1Y4-T1C2
Output type: transistor output, drain ty