LK Automation Limited
Home >> Products >> OMRON >> Inverter >> 3G3AX-AL2110 OMRON 3G3AX-AL2110 AC reactor

3G3AX-AL2110 OMRON 3G3AX-AL2110 AC reactor

Brand: OMRON
Name: AC reactor
Model: 3G3AX-AL2110
When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option.

Specification: three phase 400V.
Power: 55KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 36kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive OMRON 3G3AX-AL2110.
The high functional specifications are concentrated in the compact 3G3AX-AL2110
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function OMRON 3G3AX-AL2110.
Brake transistor built-in.
Protection function. Level: 3 phase 200V level.
Connecting resistance: 17 or more.
Internal resistance value: 120W, 20W.
In 3G3MX2 with the use of the braking resistor, can shorten the motor deceleration time.
Alarm output terminal of regenerative braking unit.
The temperature relay built-in resistance or braking resistance optional activation,
A circuit to cut off the main power supply of the frequency converter OMRON 3G3AX-AL2110. When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor OMRON AC reactor.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option. Function name: 3 phase 200V OMRON AC reactor.
Power: 7.5KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 3.4KG.
Dimension (w * h) 260mm *:140.
Outline dimension (deep):155mm.
Mechanical automation concept.
Positioning function OMRON AC reactor.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Function name: 3 phase 400V.
Power: 0.75KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.6KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):170. 3G3AX-AL2110. 5mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 00 OMRON 3G3AX-AL2110. 5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H.


...More relevant models >>>>