Inverter input power: 3 phase / single phase AC200V.
Weight: 1.3KG.
Standard applicable line diameter: 2 square mm or more.
Used to suppress harmonic currents generated by a transducer.
And it can be used with AC reactor.
Specification: three phase 200V.
Power: 2.2KW.
Maximum output voltage: three phase AC200 ~ 240V (input voltage correspondence).
Rated voltage: three phase 240V ~ 50/60Hz AC200.
Weight: about 3kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive OMRON 3G3AX-DL2007.
The high functional specifications are concentrated in the compact
3G3AX-DL2007
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function OMRON 3G3AX-DL2007.
Brake transistor built-in.
Protection function. Specification: three phase 400V.
Power: 0.75KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 3kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive OMRON 3G3AX-DL2007.
The high functional specifications are concentrated in the compact.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function) OMRON DC reactor.
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function OMRON DC reactor.
Brake transistor built-in.
Protection function. Specification: small.
Impact resistance: 120W.
Resistance to impact resistance: 100.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resistor.
When the temperature relay of the braking resistor is activated, a circuit for cuttinng the main power supply of the frequency converter is formed OMRON DC reactor 3G3AX-DL2007. Inverter input power: 3 phase / single phase AC200V.
Weight: 1.6KG.
Standard applicable line diameter: 2 square mm or more.
Used to suppress harmonicc currents generated by a transducer OMRON 3G3AX-DL2007.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor.