Power: 30kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.)
MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 55kw.
SLD converter rated current: 116A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup MITSUBISHI FR-HEL-H30K
FR-HEL-H30K
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drive motor MITSUBISHI FR-HEL-H30K.
In the state of the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor).
Other manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving MITSUBISHI FR-HEL-H30K. MITSUBISHI inverter FR-A720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 2.2KW.
Inverter output for the PWM wave, containing more harmonic MITSUBISHI AC reactor.
Frequency conversion power sensor through the input voltage and current signals to exchange sampling,
Sampling value through cable, optical fiber and other transmission systems and digital input frequency conversion power analyzer,
The sampling value of the voltage and current is calculated by the digital input frequency conversion power analyzer,
It can obtain the parameters such as voltage effective value, current effective value, fundamental wave voltage, fundamental current, harmonic voltage, harmonic current, active power, fundamental wave power and harmonic power MITSUBISHI AC reactor MITSUBISHI AC reactor. MITSUBISHI inverter series: FR-A800.
Voltage level: three phase 400V.
Power: 37kw.
SLD converter rated current: 93A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Mirror like ultra fine processing.
In order to adapt to the new material diversification, the machine adopts the most cutting-edge technology, more than ever more slim hard.
In order to be able to realize the fine cutting, grinding on the hard and hard material,
The need for hiigh-speed operation has become more and more strong FR-HEL-H30K.
In order to cope with the increasing demand of logistics, every port in the world has a crane in every day.
A container filled with cargo.
We can achieve a new type of inverrter products under the conditions of low speed and high torque to achieve smooth cargo handling operations,
Carry on the smooth movement to the heavy MITSUBISHI FR-HEL-H30K.