Brand: MITSUBISHI
Name: Extended SRAM card
Model: NZ2MC-16MBS
Capacity: 16MB.
Security CPU not supported.

Analog input channel number: 8CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Common
Conversion speed: 80 s/CH.
Channel to channel insulation.
Absolute maximum input: plus or minus 15V MITSUBISHI NZ2MC-16MBS.
External wiring connection mode: 18 point screw terminal.
Voltage input
The analog input voltage: DC - 10 - 10V NZ2MC-16MBS
Digital output value: 32000 ~ 32000.
Current input
Analog input current: -.
Digital output value: -.
16 bit high resolution (1/32000).
No program can perform scaling and conversion operations.
The most suitable for the requirements of speed and accuracy of the detection equipment MITSUBISHI NZ2MC-16MBS.
Easy to filter high frequency interference.
Execute event driven programs via alarm output.
Through the engineering software, the output of arbitrary analog waveform data.
Reduce downtime and reduce maintenance costs through anomaly detection
Works3 GX can be used to easily set the critical value of the input and output signals.
Can quickly detect the abnormal signal, so it can shorten the downtime, reduce maintenance costs MITSUBISHI NZ2MC-16MBS.
Channel insulation can ensure the accurate signal transceiver.
Model with " -G " module in the channel between the insulation,
Isolation amplifiers are not required to prevent inter channel current and interference current. Differential input, transistor (drain type) output MITSUBISHI Programmable logic controller CPU.
Channel number: 2CH.
External wiring connection mode: 40 pin connector
Count input signal: there
Single phase input (single frequency / double frequency)
Dual phase input (single frequency and double frequency /4)
CW/CCW input: there
The signal level (phi A, Phi B): EIA standard RS-422-A differential line driver level MITSUBISHI Programmable logic controller CPU.
PWM output function can be output through the highest frequency of 200kHz, minimum ON 100ns width of the PWM waveform of any duty cycle MITSUBISHI Programmable logic controller CPU.
In addition, the output cycle and duty cycle can be changed when the output PWM,
The use of the most suitable for the use of continuous PWM signal flow control. Input points: 16 points.
Rated input voltage and frequency: DC24V.
Rated input current: 6.0mA.
Response time: 5 S ~ 70ms.
Common way: 8 point / public end (positive public end).
Interrupt function: have.
External wiring connection mode: 18 point screw terminal.
The input module is the most used module in the control system.
According to the input voltage, the input points of different, choose the most suitable user needs of the module.
1 modules are equipped with a variety of functions.
Can be through a single input module to 1 points for the unit to set the high speed response, interrupt input function.
In addition, the public ennd of the module can be freely selected as the common end of the positive pole and the negative pole NZ2MC-16MBS.
It is not necessary to use different modules according to the input specifications and functions, and reduce the number of mmodules,
Therefore slot occupied quantity can be reduced by 20% than in the past, the deployment cost can be reduced by 60% compared with the previous MITSUBISHI NZ2MC-16MBS.