Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and undervoltages.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
Detected voltage: DC.
Compact, Economical Plug-in Type Voltage.
Sensing Relay.
DPDT output contacts expand the application of the Sensor to,
wide-ranging fields including control, alarms, and indication.
Voltage control is possible in the same easy manner as electro,
magnetic relays, as the output relay of the sensor can be driven,
directly with a detection signal OMRON K8AK-VW Series.
Wide voltage setting range with fine setting capability
K8AK-VW Series Category: incidental cover with under voltage detection function.
Structure: DIN guide rail mounting type.
Capacity: 50W.
Output voltage: 24V.
Output current: 2.2A.
Alarm output: source type.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device OMRON K8AK-VW Series.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free OMRON K8AK-VW Series.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer OMRON Single-phase Overvoltage/Undervoltage Relay. )
Meet F47-0200 SEMI standards OMRON Single-phase Overvoltage/Undervoltage Relay. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of insulation in,
electrical devices OMRON Single-phase Overvoltage/Undervoltage Relay.
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutually compatible.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease. Power ratings: 100 W.
Output voltage: 48 V.
Output current: 2.1 A.
Boost current: 4.2 A.
Newly Released High-capacity 240-W Models in S8EX-series Lineup.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models.
Lineup of models with from 5 to 48-VDC output.
voltages.
All Models.
Approved standards::
UL60950-1, cUR CSA C22 K8AK-VW Series. 2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonicc current standard in EN OMRON K8AK-VW Series.
61000-3-2 (50-W to 240-W models).
The top class in industry for compact size.
Boost current output (some models excluded).