Category: incidental cover type.
Structure: DIN guide rail mounting type.
Capacity: 50W.
Output voltage: 5V.
Output current: 10A.
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
Power failure detection function with built-in hint output voltage abnormity.
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Suitable core size: 0.5 to 0.75 mm.
Minimum order: 100.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking OMRON S8VM-05005CD.
Features the same degree of protection (IP67) as M12 connectors
S8VM-05005CD
A full line-up of models is planned.
Connectors with Cables are UL approved. Sensor type and connection: 3 line DC (NPN) /2 line 3-4.
Actuator connection: actuator connection 1-4.
Port number: 8.
Cable length: 5m.
This series contains the optimal control case of the new thin,
Light connector terminal box, has better,
Environmental resistance and centralized management of I/O sensor connector,
Therefore, less artificial OMRON S8VM-05005CD.
Wear resistant thin, protection grade can reach IP67.
Suitable for photoelectric sensor,
Proximity sensor and sensor with I/O connector (M12) limit switch.
In addition, due to the increase of the rated current, the ground terminal is increased,
So it can support and connect the valve solenoid OMRON S8VM-05005CD.
Contains power and action indicator light.
No matter how many ports are used, the installation method is used,
To ensure that the system can be easily expanded. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control OMRON Switching Mode Power Supply.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output OMRON Switching Mode Power Supply.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control OMROON Switching Mode Power Supply S8VM-05005CD.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads OMRON S8VM-05005CD.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).