Category: incidental cover type.
Structure: DIN guide rail mounting type.
Capacity: 30W.
Output voltage: 24V.
Output current: 1.3A.
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
Power failure detection function with built-in hint output voltage abnormity.
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Type: S8JC-ZS series models list.
Meet the criteria: CE (EN50178).
Configuration: power supply with cover; bottom surface mounting.
Input voltage: 200 ~ 240VAC.
Rated power: 15W.
Output voltage: 5VDC.
Output current: 3.0A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market OMRON S8VM-03024CD.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time
S8VM-03024CD Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output OMRON S8VM-03024CD.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control OMRON S8VM-03024CD.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2 OMRON Switching Mode Power Supply.
CE marking and cUL certified (K8AC-H2@@@). Sensor type and wiring: 3-wire DC PNP/2-wire DC 1-4 OMRON Switching Mode Power Supply.
Actuator wiring: Actuator wiring 3-4.
No. of ports: 4.
No. of I/O: 4.
Simple Wiring of Sensor Actuators.
Greatly reduce wiring in combination with the Smartclick XS5.
Insert the connector and turn 1/8 of a turn to lock the connectors.
Higher rated current to enable output applications OMRON Switching Mode Power Supply.
Use previous M12 screw connectors. Size: K8AB-TH 22.5 × 90 × 100 mm.
Supply voltage: 100 to 240 VAC.
Type: Temperature input.
Number of outputs: 1 (relay).
Input type: Thermocouple/Pt100.
Setting unit (setting range): Unit: 1°C/°F (0 to 399°C/°F).
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitooring S8VM-03024CD.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored.
Temperature monitoring in slim design with a width of just 22.5 mm.
Simple function settings using DIP switch.
Universal-inpput support for thermocouple or Pt100 sensor input OMRON S8VM-03024CD.
Selectable output relay: Non-fail safe/fail safe.
Alarm status identification with LED indicator.