Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A).
Operation: Momentary operation (Self-resetting).
Case color: Black.
Output: SPDT.
Lighting: LED; 5 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness OMRON CPM1A-CIF13.
Three-color models (green, orange, red; chameleon lighting)
CPM1A-CIF13
included in lineup. Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.130 A; 60 Hz, 0.110 A .
Rated input: 50 Hz, 20 W; 60 Hz, 18 W.
Rated rotational speed: 50 Hz, 2700 r/min; 60 Hz, 3100 r/min OMRON CPM1A-CIF13.
Maximum flow rate: 50 Hz, 2 . 6 m3/min; 60 Hz, 3.0 m3/min.
Maximum static pressure: 50 Hz, 66.6 Pa; 60 Hz, 58.8 Pa.
Noise: 50 Hz, 42 dB; 60 Hz, 46 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation OMRON CPM1A-CIF13.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series .
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Top plunger, Roller.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard operating temperature range:
-40°C to +100°C (standard type).
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approoved model .) Ouutputs: Time-limit contact CPM1A-CIF13.
Supply voltage: 110 VAC (50/60 Hz); 220 VAC (50/60 Hz).
A wide star-time range (up to 120 seconds) and star-delta,
transfer time range (up to 1.0 seconds).
Setting rings (order separately) to enable connsiistent settings,
and to limit the setting range CPM1A-CIF13.
Panel Covers (order separately) to enable various panel designs.
Approved by UL, CSA, CE and CCC.
CPM1A-CIF13 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=CPM1A-CIF13&select=5