Operation control mode: stored procedure repeated operation.
Built in IE CC-Link.
Input / output points: 4096 points.
Program capacity: 160K step.
Easy to collect and display the value of soft component.
With simple parameter setting, the value of the soft component can be collected as the record data,
Save to the SD memory card, or through the USB/ Ethernet for real-time monitoring FX1S-14MT-D.
Using the data collected by the recording function to support the Unicode text format,
Can be easily recognized by LogViewer GX and spreadsheet software
FX1S-14MT-D
In addition, LogViewer GX can also be used to monitor the function of real time,
Easily confirm the time of small changes in the object''s soft components FX1S-14MT-D.
These features can be traced back to improve and set up a fault when the commissioning of a great help . Type: general purpose AC servo amplifier MR-E series.
Rated output: 0.1kw.
Interface type: general purpose pulse interface.
KH003 special mark for Super MR-E.
High performance and easy to operate, reduce work load.
Enhanced system cost performance FX1S-14MT-D.
High performance, high precision positioning (servo motor encoder resolution: 131072) .
High response.
Suppression of vibration by adaptive vibration suppression control.
Using personal computer and servo setup software to optimize tuning.
Has 2 types of interfaces:
Position control and speed control with pulse train interface.
The analog input interface is used for speed control and torque control. Analog input points: 4 points (PT1000/Nil000).
Resolution: 0.1 degrees.
Weight: 0.1kg.
Dimensions: 17.6 x 90 x 89.5.
FX3U-4AD-PNK-ADP is a PT1000/Nil000 temperature sensor with analog input adapter.
Thermocouple (K type, J type) and PT1000/Nil000 temperature sensor with analog input adapter.
-100~1000 degree can be measured by 4 channels.
No programming to send data to FX3 series.
Connect FX3SA, FX3S, FX3GA, FX3G, FX3U,
Need to convert adapter or function extension board. 1 channels.
50/10kpps.
Count input signal: DC5/12/24V.
External input: DC5/12/24V.
Output: Transistor (open collector).
Output: DC12/24V, 0.1A/1 point, 0.8A/1 common.
47 point terminal station.
How to determine the input / output device of MITSUBISHI plc.
According to the control requirements of the system,
All input devices and output devices required for the determination of the system,
To determine the input / output device relatedd to the MITSUBISHI PLC,
Too determine the I/O PLC points MITSUBISHI FX1S-14MT-D.
Detailed analysis of the process and work characteristics of the controlled object,
To understand the coordination between the controlled object machine, electricity and liquid,
The control reequirements of the controlled object for MITSUBISHI PLC control system are put forward,
Determine the control program, to develop a design task book MITSUBISHI FX1S-14MT-D.
FX1S-14MT-D Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FX1S-14MT-D&select=5